Security & Sensors · Hardware
Smart Motion & Environmental Sensors
Temperature, humidity, wind and doors across the site — wireless, on battery-powered nodes.

Overview
The problem. Environmental quantities are critical in industrial sites but often go unmeasured: cold-room temperature, humidity in chemical stores, wind on crane and port yards (load sway, crane lock-out rules), panel and ambient temperature on solar farms, tank and well covers left open, motion outside working hours. There is no cable route for a wired sensor network; Wi-Fi/BLE sensors struggle with coverage and batteries; cloud IoT sensors require subscriptions and closed platforms. Alarms such as high wind or temperature drift do not reach anyone in time.
The solution. The sensor node family fits different sensor heads onto a single battery-powered LoRa node. The node sends periodic measurements (e.g. every 10 minutes) and an instant alarm packet when a threshold is crossed; the Wireless Gateway / RTU passes the data to SCADA or to the Telemetry & Process Intelligence layer via Modbus, MQTT or CSV, and WR-001 carries alarms to the staff member's pocket. The mains-powered version adds a local relay output: a crane lock relay when the wind limit is exceeded, a fan when a temperature threshold is crossed.
The family. The anemometer housing and PCB are designed by Elmes; the temperature-humidity node moves from the earlier SHT11-based design to modern SHT3x/SHT4x sensors; the level and door-contact nodes are derived from existing I/O firmware. Thermal, infrared and laser sensors are planned members of the family; they have no prototypes yet and are listed as coming soon.


This product is in development or field testing. Contact us for technical information, pilot use and a preliminary quotation.
Features
- One node, interchangeable heads: temperature-humidity, anemometer, level and door/motion heads share one PCB family; the firmware profile recognizes the fitted head.
- Local threshold relay (mains-powered): wind limit → crane lock; temperature → fan/heater; works without a central unit.
- Elmes-designed anemometer housing: cup rotor, wind vane and body; 3D-printed prototype; gust and average values are computed on the node.
- LED display option: a large temperature-humidity display (P10 LED panel) for warehouses and production areas.
- TargetOptions: solar power, 868 MHz version, WR-001 pocket alarms, hydrostatic level, dual-technology PIR.
- TargetEvent buffer and alarm-rate reporting: events are buffered on the node; reporting frequency increases during an alarm.
- TargetSensor fusion: prediction and early warning from multiple nodes' data in the Telemetry & Process Intelligence layer, shared with Firesens. The AI-assisted false-alarm filter runs in this layer, not on the node.
- TargetThermal, infrared and laser sensors: a thermal camera, infrared beam barrier and laser distance sensor are planned members of the family; there are no prototypes yet.
Sensor family
| Model code | Sensor | Measurement | Output | Power | Status | Request information |
|---|---|---|---|---|---|---|
| SN-THTarget | Temperature-humidity (SHT3x/SHT4x) | −40…+125 °C, 0–100 %RH | LoRa; optional LED display | Battery | Prototype; being updated with a new sensor | Request information: SN-TH |
| SN-WS | Anemometer + wind vane | Wind speed 0–50 m/s, direction in 16 sectors | LoRa; wind-limit relay (mains-powered) | Battery / solar | Prototype | Request information: SN-WS |
| SN-LV | Level: 4-step float / hydrostatic 4–20 mA | Level steps / cm | LoRa | Battery | Base design in the field (well/tank control) | Request information: SN-LV |
| SN-DCTarget | Door/cover contact + tamper | Open/closed, time held open | LoRa | Battery | Planned | Request information: SN-DC |
| SN-PIRTarget | Motion (PIR) + door contact | Motion event | LoRa | Battery | Planned | Request information: SN-PIR |
| SN-TPTarget | Temperature probe (PT100 / thermocouple / DS18B20) | −50…+400 °C (depending on probe type) | LoRa | Battery | Planned | Request information: SN-TP |
| SN-IR / SN-LZ / SN-THCTarget | Infrared beam barrier / laser distance / thermal camera | — | — | — | Planned; no prototype yet | Request information: SN-IR / SN-LZ / SN-THC |
Specifications
Values marked “Target” are design targets, next-generation values or chip-vendor data; they are updated as measurement and certification are completed.
| Frequency / channels | 433.05–434.79 MHz, 8 channels (SX1268); 868 MHz version |
|---|---|
| Output power / sensitivity | +14…+22 dBm / −129 dBm @ SF11 |
| Modulation | LoRa SF7–12; packets ≤ 32 bytes |
| Antenna | Internal or u.FL → SMA on the housing; SMA on the anemometer mast |
| Open field | ≥ 3000 m (SF10, 2 dBi external antenna, 3 m height)Target |
|---|---|
| Indoors / warehouse | ≥ 150 mTarget |
| Encryption / addressing | AES-128-CCM; NetID + 16-bit addressTarget |
|---|---|
| Pairing | Registration on the gateway by UID |
| Reporting interval | 1 min–24 h; immediate on alarm (< 2 s) |
| Offline detection | After 3 missed reports |
| Battery | Li-SOCl2 AA/C 3.6 V or 2×AA; < 10 µA in sleep; measurement + TX ~120 mA × 100 ms |
|---|---|
| Battery life | ≥ 3 years @ 10 min reporting (temperature-humidity, door); solar panel + Li-ion recommended for the anemometer, which counts continuouslyTarget |
| Mains-powered version | 9–36 VDC; relay output via the EC-DIO8 carrier board |
| SN-TH temperature-humidity | SHT3x/4x capacitive: −40…+125 °C ±0.2 °C, 0–100 %RH ±2 %RH (datasheet); earlier SHT11 design ±0.4 °C / ±3 %RH |
|---|---|
| SN-WS wind | Cup anemometer (pulse) + wind vane (Hall/pot): 0–50 m/s after calibration; direction in 16 sectors ±11°Target |
| SN-WS starting threshold | ≤ 1 m/sTarget |
| SN-LV level | 4-step float (contact) |
| SN-LV hydrostatic level | 4–20 mA, 0–5 mTarget |
| SN-DC door contact | Magnetic contact; open/closed, time held open; tamper |
| SN-PIR motion | PIR 90–110°, 8–12 m (module datasheet); dual technology optionalTarget |
| SN-IR / SN-LZ / SN-THC | Infrared beam barrier 5–100 m, laser distance, thermal camera; no prototype yetTarget |
| Sensitivity settings | Upper/lower threshold + hysteresis, N consecutive samples, gust filter; PIR sensitivity levels |
| False-alarm measures | Hysteresis, consecutive samples, sensor fault flag |
| Multi-sensor fusion | In the Telemetry & Process Intelligence layerTarget |
| Output type | LoRa (standard); 2 × 5 A relays (mains-powered version); no 4–20 mA output (Modbus via the gateway) |
|---|---|
| Additional inputs | 2 × contact, 1 × analog 4–20 mA / 0–10 VTarget |
| Service interface | SWD / UART |
| Node housing | IP65 wall box, approx. 100 × 100 × 60 mmTarget |
|---|---|
| Anemometer body | Elmes 3D design, ABS/ASA print; mast clamp |
| Anemometer production body | Injection-moldedTarget |
| Mounting | Wall / mast / ceiling (PIR) |
| Operating conditions | −30…+60 °C (Li-SOCl2); 100 % humidity (IP65/67); no anti-icing heater on the anemometer |
| Warranty | 2 years; batteries and sensor heads are consumablesTarget |
|---|
Applications
- Crane and port yards
- Solar / wind farms
- Cold storage
- Food and pharma warehouses
- Chemical and paint plants
- Greenhouses and agriculture
- Water tanks and wells
- Perimeter security
- Crane and port yards: crane lock-out at the wind speed limit; an optional module for the Wireless Crane Control System.
- Solar / wind farms: ambient and panel temperature, wind, cabinet door contact.
- Cold rooms, food and pharma warehouses: temperature-humidity monitoring and alarms; large LED display.
- Chemical and paint plants: humidity and temperature; sensor fusion with the Wireless Fire Alarm System (Firesens).
- Greenhouses and agriculture: temperature, humidity and wind; hybrid greenhouse automation with the Wireless Irrigation Control System is planned.
- Water tanks and wells: level floats and cover contacts (Wireless Well & Tank Control System).
- Perimeter security: after-hours motion, door and cover openings, together with the Wireless Guard Patrol System and Smart Door Control & Access.
Compliance & documentation
The sensor family is at the prototype stage; product documentation is being prepared according to the plan below. Manufacturer documents for the sensing elements are added to the product file.
- TargetCE – RED 2014/53/EU (EN 300 220-2, EN 301 489-1/-3)
- TargetEMC
- TargetRoHS declaration
- TargetEN 50131-2-2 — PIR motion detector security gradeOptional
- Out of scopeISO 17713-1 — meteorological anemometer calibrationThe anemometer is intended as an industrial indicator
- TargetCE declaration of conformity, datasheets, installation guide, anemometer calibration procedure and Modbus map
Frequently asked questions
Which sensors are available?
Today, at prototype and base-design level: temperature-humidity, anemometer (wind speed and direction), level float and door contact. Thermal camera, infrared beam barrier and laser distance sensors are planned members of the family; there are no prototypes yet.
How long does the battery last?
The target is 3 years or more at 10-minute reporting (temperature-humidity and door nodes). Because the anemometer counts continuously, a solar panel with a rechargeable battery is recommended. Measured results will be added to the specifications.
Can it stop a crane at the wind limit?
Yes, in the mains-powered version: the local relay signals the crane lock circuit when the wind threshold is exceeded, and the safe state on RF loss is configurable. It is an optional module for the Wireless Crane Control System.
Where can I see the data?
Through the Wireless Gateway / RTU via web, Modbus or MQTT; in your own SCADA or in the Telemetry & Process Intelligence cloud dashboard (planned). Alarms also go to the WR-001 pocket pager.
How do you prevent false alarms?
With hysteresis, consecutive samples, a gust filter and sensor fault detection. Multi-sensor fusion is planned; the AI-assisted filter runs in that layer, not on the node.
What is the range?
The battery node uses an internal or housing-mounted antenna; with the gateway's external antenna, kilometer-level range in open field is the target, to be confirmed by measurement. Repeaters are used inside warehouses.
Can it feed 4–20 mA to my existing PLC?
The node does not; the gateway provides the data over Modbus TCP. If a 4–20 mA output is required, the EC-AIO board from the I/O Carrier Boards family is used.
What about the warranty?
A 2-year warranty is planned; batteries and sensor heads are consumables.
Get information about this product
Our engineering team replies within 24 hours.
Related products
Coming soonModules, Boards & GatewaysWireless Gateway / RTU
Connect every LoRa node in the field to SCADA, the cloud and PLCs with a single box.
View details: Wireless Gateway / RTU
Coming soonAutomation & TelemetryTelemetry & Process Intelligence
Field data into semantic memory, semantic memory into decisions.
Early access / pilot
View details: Telemetry & Process Intelligence
Coming soonRF & Wireless SystemsWR-001 LoRa Wireless Alarm / Call Pager
The alarm in your pocket — everyone sees who acknowledged it.
View details: WR-001 LoRa Wireless Alarm / Call Pager