Skip to main content

Security & Sensors · Hardware

Smart Motion & Environmental Sensors

Coming soon

Temperature, humidity, wind and doors across the site — wireless, on battery-powered nodes.

SN-WS wind sensor kit: anemometer and wind vane on a pole-clamped arm, IP65 node box with antenna and cable glands

Overview

The problem. Environmental quantities are critical in industrial sites but often go unmeasured: cold-room temperature, humidity in chemical stores, wind on crane and port yards (load sway, crane lock-out rules), panel and ambient temperature on solar farms, tank and well covers left open, motion outside working hours. There is no cable route for a wired sensor network; Wi-Fi/BLE sensors struggle with coverage and batteries; cloud IoT sensors require subscriptions and closed platforms. Alarms such as high wind or temperature drift do not reach anyone in time.

The solution. The sensor node family fits different sensor heads onto a single battery-powered LoRa node. The node sends periodic measurements (e.g. every 10 minutes) and an instant alarm packet when a threshold is crossed; the Wireless Gateway / RTU passes the data to SCADA or to the Telemetry & Process Intelligence layer via Modbus, MQTT or CSV, and WR-001 carries alarms to the staff member's pocket. The mains-powered version adds a local relay output: a crane lock relay when the wind limit is exceeded, a fan when a temperature threshold is crossed.

The family. The anemometer housing and PCB are designed by Elmes; the temperature-humidity node moves from the earlier SHT11-based design to modern SHT3x/SHT4x sensors; the level and door-contact nodes are derived from existing I/O firmware. Thermal, infrared and laser sensors are planned members of the family; they have no prototypes yet and are listed as coming soon.

Anemometer, SN-WS node box and SN-TH temperature-humidity sensor on a rooftop mast at dusk
In use
Smart sensor family: SN-WS wind kit, SN-TH with radiation shield, SN-DC with door contact and SN-PIR motion sensor
Product family

This product is in development or field testing. Contact us for technical information, pilot use and a preliminary quotation.

Features

  • One node, interchangeable heads: temperature-humidity, anemometer, level and door/motion heads share one PCB family; the firmware profile recognizes the fitted head.
  • Local threshold relay (mains-powered): wind limit → crane lock; temperature → fan/heater; works without a central unit.
  • Elmes-designed anemometer housing: cup rotor, wind vane and body; 3D-printed prototype; gust and average values are computed on the node.
  • LED display option: a large temperature-humidity display (P10 LED panel) for warehouses and production areas.
  • TargetOptions: solar power, 868 MHz version, WR-001 pocket alarms, hydrostatic level, dual-technology PIR.
  • TargetEvent buffer and alarm-rate reporting: events are buffered on the node; reporting frequency increases during an alarm.
  • TargetSensor fusion: prediction and early warning from multiple nodes' data in the Telemetry & Process Intelligence layer, shared with Firesens. The AI-assisted false-alarm filter runs in this layer, not on the node.
  • TargetThermal, infrared and laser sensors: a thermal camera, infrared beam barrier and laser distance sensor are planned members of the family; there are no prototypes yet.

Sensor family

Sensor family
Model codeSensorMeasurementOutputPowerStatusRequest information
SN-THTargetTemperature-humidity (SHT3x/SHT4x)−40…+125 °C, 0–100 %RHLoRa; optional LED displayBatteryPrototype; being updated with a new sensorRequest information: SN-TH
SN-WSAnemometer + wind vaneWind speed 0–50 m/s, direction in 16 sectorsLoRa; wind-limit relay (mains-powered)Battery / solarPrototypeRequest information: SN-WS
SN-LVLevel: 4-step float / hydrostatic 4–20 mALevel steps / cmLoRaBatteryBase design in the field (well/tank control)Request information: SN-LV
SN-DCTargetDoor/cover contact + tamperOpen/closed, time held openLoRaBatteryPlannedRequest information: SN-DC
SN-PIRTargetMotion (PIR) + door contactMotion eventLoRaBatteryPlannedRequest information: SN-PIR
SN-TPTargetTemperature probe (PT100 / thermocouple / DS18B20)−50…+400 °C (depending on probe type)LoRaBatteryPlannedRequest information: SN-TP
SN-IR / SN-LZ / SN-THCTargetInfrared beam barrier / laser distance / thermal camera———Planned; no prototype yetRequest information: SN-IR / SN-LZ / SN-THC

Specifications

Values marked “Target” are design targets, next-generation values or chip-vendor data; they are updated as measurement and certification are completed.

Radio
Frequency / channels433.05–434.79 MHz, 8 channels (SX1268); 868 MHz version
Output power / sensitivity+14…+22 dBm / −129 dBm @ SF11
ModulationLoRa SF7–12; packets ≤ 32 bytes
AntennaInternal or u.FL → SMA on the housing; SMA on the anemometer mast
Range
Open field≥ 3000 m (SF10, 2 dBi external antenna, 3 m height)Target
Indoors / warehouse≥ 150 mTarget
Communication & security
Encryption / addressingAES-128-CCM; NetID + 16-bit addressTarget
PairingRegistration on the gateway by UID
Reporting interval1 min–24 h; immediate on alarm (< 2 s)
Offline detectionAfter 3 missed reports
Power
BatteryLi-SOCl2 AA/C 3.6 V or 2×AA; < 10 µA in sleep; measurement + TX ~120 mA × 100 ms
Battery life≥ 3 years @ 10 min reporting (temperature-humidity, door); solar panel + Li-ion recommended for the anemometer, which counts continuouslyTarget
Mains-powered version9–36 VDC; relay output via the EC-DIO8 carrier board
Measurement
SN-TH temperature-humiditySHT3x/4x capacitive: −40…+125 °C ±0.2 °C, 0–100 %RH ±2 %RH (datasheet); earlier SHT11 design ±0.4 °C / ±3 %RH
SN-WS windCup anemometer (pulse) + wind vane (Hall/pot): 0–50 m/s after calibration; direction in 16 sectors ±11°Target
SN-WS starting threshold≤ 1 m/sTarget
SN-LV level4-step float (contact)
SN-LV hydrostatic level4–20 mA, 0–5 mTarget
SN-DC door contactMagnetic contact; open/closed, time held open; tamper
SN-PIR motionPIR 90–110°, 8–12 m (module datasheet); dual technology optionalTarget
SN-IR / SN-LZ / SN-THCInfrared beam barrier 5–100 m, laser distance, thermal camera; no prototype yetTarget
Sensitivity settingsUpper/lower threshold + hysteresis, N consecutive samples, gust filter; PIR sensitivity levels
False-alarm measuresHysteresis, consecutive samples, sensor fault flag
Multi-sensor fusionIn the Telemetry & Process Intelligence layerTarget
Inputs / outputs
Output typeLoRa (standard); 2 × 5 A relays (mains-powered version); no 4–20 mA output (Modbus via the gateway)
Additional inputs2 × contact, 1 × analog 4–20 mA / 0–10 VTarget
Service interfaceSWD / UART
Mechanical & environmental
Node housingIP65 wall box, approx. 100 × 100 × 60 mmTarget
Anemometer bodyElmes 3D design, ABS/ASA print; mast clamp
Anemometer production bodyInjection-moldedTarget
MountingWall / mast / ceiling (PIR)
Operating conditions−30…+60 °C (Li-SOCl2); 100 % humidity (IP65/67); no anti-icing heater on the anemometer
Warranty & service
Warranty2 years; batteries and sensor heads are consumablesTarget

Applications

  • Crane and port yards
  • Solar / wind farms
  • Cold storage
  • Food and pharma warehouses
  • Chemical and paint plants
  • Greenhouses and agriculture
  • Water tanks and wells
  • Perimeter security

Compliance & documentation

The sensor family is at the prototype stage; product documentation is being prepared according to the plan below. Manufacturer documents for the sensing elements are added to the product file.

  • CE – RED 2014/53/EU (EN 300 220-2, EN 301 489-1/-3)
    Target
  • EMC
    Target
  • RoHS declaration
    Target
  • EN 50131-2-2 — PIR motion detector security grade
    Optional
    Target
  • ISO 17713-1 — meteorological anemometer calibration
    The anemometer is intended as an industrial indicator
    Out of scope
  • CE declaration of conformity, datasheets, installation guide, anemometer calibration procedure and Modbus map
    Target

Frequently asked questions

Which sensors are available?

Today, at prototype and base-design level: temperature-humidity, anemometer (wind speed and direction), level float and door contact. Thermal camera, infrared beam barrier and laser distance sensors are planned members of the family; there are no prototypes yet.

How long does the battery last?

The target is 3 years or more at 10-minute reporting (temperature-humidity and door nodes). Because the anemometer counts continuously, a solar panel with a rechargeable battery is recommended. Measured results will be added to the specifications.

Can it stop a crane at the wind limit?

Yes, in the mains-powered version: the local relay signals the crane lock circuit when the wind threshold is exceeded, and the safe state on RF loss is configurable. It is an optional module for the Wireless Crane Control System.

Where can I see the data?

Through the Wireless Gateway / RTU via web, Modbus or MQTT; in your own SCADA or in the Telemetry & Process Intelligence cloud dashboard (planned). Alarms also go to the WR-001 pocket pager.

How do you prevent false alarms?

With hysteresis, consecutive samples, a gust filter and sensor fault detection. Multi-sensor fusion is planned; the AI-assisted filter runs in that layer, not on the node.

What is the range?

The battery node uses an internal or housing-mounted antenna; with the gateway's external antenna, kilometer-level range in open field is the target, to be confirmed by measurement. Repeaters are used inside warehouses.

Can it feed 4–20 mA to my existing PLC?

The node does not; the gateway provides the data over Modbus TCP. If a 4–20 mA output is required, the EC-AIO board from the I/O Carrier Boards family is used.

What about the warranty?

A 2-year warranty is planned; batteries and sensor heads are consumables.

Get information about this product

Our engineering team replies within 24 hours.