Wireless Patrol Control System

Model code: ELC402

Button-based patrol and alarm control for military and civilian sites; RFID checkpoints optional.

ELC402 guard post device: IP65 outdoor enclosure with Attack, Fire and Check-in buttons, RFID area and antenna

Overview

The problem in the field. On large sites, guard posts are far from the control room; radio calls carry no identity or location, and running wired alarm lines is costly and open to sabotage. Whether a guard is on duty and alert usually cannot be verified, and after an incident there is no record of who, when and where.

The solution. The system is button-based: each guard post gets a wireless device (ELC402) with Attack, Fire and Check-in buttons. When a button is pressed, the alarm type and location appear instantly on the central panel, and the sirens and alarm contact are triggered according to the scenario. Check-in supervision prompts the guard at a set interval (e.g. 30 min); if the check-in button is not pressed within 1 minute, the control room is alerted. Once the duty roster is entered, the personnel on duty at the time of an alarm are logged.

Expansion. RFID checkpoints are optional: with an RFID card or fingerprint reader, check-ins can only be made by authorized personnel. In the Professional tier, alarm and personnel information is shown on a dynamic site plan. The roadmap covers PC/mobile monitoring and reporting, GSM/4G backup notifications, the WR-001 portable notification unit for the response team and, in the longer term, a BLE/UWB-based real-time location (RTLS) layer.

ELC402 guard post on a solar-powered pole with battery box, next to a fence and guard booth at night
In use
Patrol control components: wireless siren, ELC402, 7-inch desktop control panel, solar panel and battery kit
Product family

Features

  • Three-button alarm/check-in device (ELC402): Attack, Fire, Check-in; each alarm type has its own color/sound at the control room and its own siren assignment.
  • Check-in (alertness) supervision: adjustable interval and tolerance time; missed check-in alarm and log.
  • Duty log / roster: personnel on duty are logged at the time of an alarm (Smart and Professional tiers).
  • Independent wireless sirens: placed in any zone, with a selectable alarm assignment; audible and visual.
  • Dynamic site plan / map: alarm and personnel information on the site plan in the Professional tier.
  • RFID checkpoint (optional): hardware-ready; restricts check-ins to authorized personnel; fingerprint reader option.
  • Alarm contact output: dry contact to PLCs, auto-diallers and other security systems.
  • Solar power: for guard posts without mains power.
  • TargetOperations center software: a PC-based monitoring center application.
  • TargetPC and mobile monitoring: status monitoring, alarm notifications and reports for authorized users.
  • TargetGSM/4G backup notifications: SMS or calls from the control room via the Cellular Module 4G/NB-IoT (EM-G0C).
  • TargetPortable notification unit: alarms to the response team with the WR-001 LoRa Wireless Alarm / Call Remote.
  • TargetRTLS expansion: patrol location with BLE/UWB tags; a new layer rather than a direct upgrade of the current hardware.

System components

System components
Model codeComponentDescriptionStatusRequest a quote
ELC402Guard post deviceAttack, Fire and Check-in buttons; wirelessIn the fieldRequest a quote: ELC402
—Central panelAlarm type and location display; duty log; dry-contact alarm outputIn the fieldRequest a quote: Central panel
—Wireless sirenAudible and visual; assigned by zone and alarm typeIn the fieldRequest a quote: Wireless siren
—RFID / fingerprint readerRestricts check-ins to authorized personnelOptionalRequest a quote: RFID / fingerprint reader
—Solar panel + battery kitFor guard posts without mains powerIn the fieldRequest a quote: Solar panel + battery kit
WR-001TargetPortable notification unitAlarm notifications to the response teamPlannedRequest a quote: WR-001
—TargetGSM/4G backup notificationSMS or calls from the control roomPlannedRequest a quote: GSM/4G backup notification

Specifications

Values marked “Target” are design targets, next-generation values or chip-vendor data; they are updated as measurement and certification are completed.

Current system
Post deviceELC402: Attack, Fire, Check-in buttons
Check-in supervisionAdjustable interval (e.g. 30 min), 1 min tolerance; missed check-in alarm and log
NotificationCentral panel, wireless siren (audible + visual), dry-contact alarm output
IdentificationRFID card / fingerprint reader, optional
CommunicationClosed on-site RF network; no internet or GSM required
Post powerSolar panel + battery kit option
Radio (new series)
Frequency band433.05–434.79 MHz, 8 channels; 868 MHz as an optionTarget
Output power+22 dBm, adjustableTarget
Receiver sensitivity−129 dBm @ SF11 (chip datasheet)Target
ModulationLoRa SF9–SF11Target
AntennaSMA at the control room; PCB antenna or SMA on post devicesTarget
Range
Open field≥ 2000 m (SF11, 2 m height)Target
Indoor / within the compound≥ 500 m; extendable with repeatersTarget
Communication & security
EncryptionAES-128-CCMTarget
Addressing16-bit network ID + 16-bit addressTarget
PairingIn the field, from the control roomTarget
Systems on the same site≥ 8 networksTarget
Performance & fail-safe
Alarm latency≤ 1 sTarget
Check-in interval1–240 min; tolerance 1–10 minTarget
Missing-post detection3 report intervalsTarget
WatchdogIndependent hardware watchdog (IWDG)Target
Inputs / outputs
Post device (new series)3 buttons + RFID / fingerprint + tamper inputTarget
Power
Siren supply12–24 VDC + battery backupTarget
Mechanical & environmental
Control unitPanel-mount or desktopTarget
Post device housingIP65 outdoor, UV-resistantTarget
Operating temperature−25…+60 °C (post device)Target
HumidityUp to 95 %, non-condensingTarget
Warranty & service
Warranty2 years; manufacturing and service in Ankara

Applications

  • Military barracks, depots and facilities
  • Ports
  • Industrial estates and plant perimeters
  • Critical infrastructure (energy, water)
  • Officers' clubs, housing and campuses
  • Private security patrol points
  • Construction sites

The system runs as a closed on-site network and needs no internet or GSM connection. The control room's alarm contact output connects to a PLC, an auto-dialler or a security panel. The product is positioned as a guard patrol and check-in control system, not as an intruder alarm system.

Adding posts and changing parameters is done by Elmes or an authorized installer.

Compliance & documentation

There is no product-level CE declaration of conformity or RED test report yet; documentation is being prepared according to the plan below. The product is positioned as a guard patrol and check-in control system, not as an intruder alarm system.

  • CE – RED 2014/53/EU (EN 300 220-2, EN 301 489-1/-3)
    Starting at module level
    Target
  • LVD / EN 62368-1 — control unit and adapters
    Target
  • RoHS declaration
    Target
  • KVKK (Turkish data protection law) — data retention policy in the software for personnel records and RFID data
    Target
  • CE declaration of conformity, user manual and wiring diagram
    Target
  • EN 50131 series — intruder alarm systems
    The product is positioned as a patrol / check-in control system
    Out of scope

Frequently asked questions

Is RFID mandatory?

No. The system is button-based; RFID identification is optional (the hardware is ready for it). It is added when check-ins must be made by authorized personnel only.

Will it interfere with another Elmes system on the same compound or a neighboring site?

Every network has its own ID; packets with a different ID are ignored. The new series targets at least 8 independent networks through channel and network-ID combinations.

What if there is no mains power at a guard post?

The post runs on a solar panel + battery kit; a battery-powered device option is planned.

Is an internet or GSM connection required?

No. The system runs as a closed on-site network; GSM/4G is only for optional backup notifications, which are planned.

Can it connect to an existing security system?

Yes: the control room's alarm contact output connects to a PLC, an auto-dialler or a security panel through a dry contact. The Professional tier also provides a site-plan display.

How can the range be extended?

Use an external or high-gain antenna (Industrial RF Antenna Series) and mount the control-room antenna high; add a second central receiver if needed. Repeater support is planned.

What happens if the guard does not press the button?

When the check-in interval ends, the device prompts the guard; if the button is not pressed within the tolerance time, the control room raises a “missed check-in” alarm and the event is logged.

What about warranty and service?

2-year warranty; manufacturing and service in Ankara. Adding posts and changing parameters is done by Elmes or an authorized installer.